The
AIM Series 9010 is the IR probe design of the very
popular E-6200 IR In-Situ Stack Gas Monitors: featuring
dual beam, dual wavelength rationing, double-pass,
non-dispersive infrared (NDI R) analysis.
These instruments incorporate mechanical and optical
features which have been refined through over 30 years
of practical field experience, state-of-the-art design,
and over 4,000 installations world-wide. AIM is
experienced in the development, installation, operation
and compliance testing of emissions monitoring
instrumentation.
This includes single and multi-component UV, VIS, and
IR absorption gas analyzers, gas filter correlation
analyzers, transmissometers, single and multiple-pass
optical systems, fiber-optic coupled systems, and
long-path (open-path) ambient analyzers.
Features
● Patented Technology with Over 30 Years Experience
● Single Penetration of Gas Stream
● Calibrate In Place In the Probe
● Expandable To Measure Six Gases Standard, Ten On
Special Order
● Meets US and International EPA, State and Local Agency
Requirement
● Accurate Measurements
● Fast Response
● Automatic Calibration
● Automatic Temperature Correction
● Digital Circuitry and Signal Transmission
● Stable Alignment
● EPA-Approved In-Place CGA Calibration Verification
● Proven Design
● Expandable
● Low Maintenance
Ranges Adjustable from ppm to percent (%)
levels, depending upon pathlength; multiple
outputs/ranges available.
Typical System Configuration:
SO2 0 - 1000 to 0 - 5000 ppm v/v
NOx 0 - 250 to 0 - 2500 ppm v/v
CO2 0 - 5 to 0 - 30% /vol
CO 0 - 100 ppm v/v to 0 - 10%
HCI 0 - 100 to 0 - 1000 ppm v/v
H2O 0 - 25 to 0 - 40%
Accuracy: Better than ± 2% of full scale
Repeatability: Better than ± 1% of full scale
Linearity: Better than ± 1% of full scale
Zero Drift: Less than ± 1% of full scale in 30 days
Span Drift: Less than ± 1% of full scale in 30 days
Response Time: 1 to 15 minutes, Typ., operator
selectable
|