Target Five Gas
Monitor
Features
This versatile gas detector features internal sampling
pump and remote display capability.
· Up to 5 Sensors, including Broad-Range Toxic
· Simultaneous Display of All Sensor Readings
· Internal Sample Pump
· Remote Display Capability
· 10 Preprogrammed Combustibles
· Datalogging
· Push-button Cal and Auto Zero
· Designed to Minimize RFI
· Intrinsically Safe
Specifications
Display: LCD with backlight, 4 lines, 20 characters
Sensors: Combustible: Catalytic
Oxygen & Toxic: Electrochemical
Broad-Range Hydrocarbons: Metallic Oxide Semiconductor
(MOS)
Power: Nickel metal hydride battery pack or optional
alkaline
Size: 194 x 119 x 58 mm
Weight: 1 Kg
Gases Detected Range Gases Detected Range
Combustible 0-100% LEL Oxygen 0-30.0% by Vol.
Carbon monoxide 0-500 ppm Hydrogen sulfide 0-200 ppm
Broad-range Chlorine 0-9.9 ppm
hydrocarbons 0-200 ppm Sulfur dioxide 0-30.0 ppm
Nitrogen dioxide 0-30.0 ppm Hydrogen chloride 0-20.0 ppm
Ammonia 0-100 ppm Ozone 0-3.00 ppm
Note: Other gas sensors available

Enguard 97D
Controller with Integral or Remote Toxic Sensor
The economical ENGUARD 97D Stand-Alone controller
features either an integral toxic gas sensor or an
optional remote sensor and cable. Electrochemical
sensors are available for O2 and a wide range of toxic
gases.
Features
· Integral or Remote Sensor and Cable
· Audio and Visual Alarms ■ 4-20 mA Output Signal
· 3 Factory Programmable Alarms ■ 5 Vdc TTL Outputs
· 85-265 Vac, or 24 Vdc Power
· IP 65, Polycarbonate Enclosure ■ Digital Display
· Pushbutton Calibration ■ 1 Alarm Relay, User
Selectable
SDS-97D Series
Sensor/Transmitters
SDS-97D
Series Sensor/Transmitters utilize electrochemical type
cells to detect the target gas. These cells consist of
electrodes, electrolyte and an air/liquid separation
barrier. Gas molecules
enter the cell and, as a result of an
oxidation/reduction reaction, generate an electrical
current proportional to the gas concentration.
This current is measured, conditioned, converted to the
gas concentration, digitally displayed and transmitted
as a 4-20 mA output signal. ENMET offers a variety of
multi-channel controller/alarm modules that provide the
24 Vdc loop power and receive the 4-20 mA signal from
the sensor/transmitters. These sensor/transmitters can
also be connected to various computer based
instrumentation, PLCs, etc.
The use of a gas sampler generally improves monitoring
performance for all gases. It is particularly
recommended for Cl2, HCl, AsH3, and it is required for
monitoring HF and O3.
The standard SDS-97D Sensor/Transmitters (P/N
10022-XXXX) incorporate an external push button for
non-intrusive zeroing and gas calibration of the device.
An optional version of the SDS-97D
Sensor/Transmitters (P/N 10021-XXXX) feature a
communication port and hand-held programming module (P/N
10021-001) which facilitate the elimination of the need
for on-site gas calibration.
Contact ENMET for details regarding the Precalibrated
Sensor Exchange Program.
Features
■ Non-intrusive push button calibration
■ Excellent chemical selectivity
■ 4-20 mA output, 24 Vdc loop powered
■ One-person calibration
■ Digital display
■ Electrochemical sensors
■ RFI/EMI resistant
■ Optional Precalibrated Sensor Exchange
|