Series 3000 Mkll Transmitter with Sensor Australian Dynamic Technologies 10:22 am
Honeywell Series 3000 MKII Transmitter - Gas Detector

Series 3000 Mkll Transmitter with Sensor

The Series 3000 Mkll is built to handle oxygen and toxic gas hazards in atmospheres that are deemed to be possibly explosive. Both indoor as well as outdoor use are possible and the device has been designed to be highly versatile. The housing of the Series 3000 MkII is flameproof and it has been manufactured for predominate use in Zone 1 applications.

Specific gas types applicable to this device include Chlorine (Cl2), Hydrogen (H2) Ammonia (NH3), Chlorine Dioxide (ClO2), Hydrogen Chloride (HCl), and Carbon Monoxide (CO).

A remote mount kit (optional accessory) can be added to the Series 3000 MkII to allow it to be installed in a Zone 0 environment. The MkIII model (note the difference to MkII) can be used with an IS barrier which allows the whole transmitter to be used for applications in Zone 0 environments.

A great choice for retrofit or new installations due to the loop powered 4-20 mA connection which means the device is low powered. The usual Honeywell ease of use is prevalent with the Series 3000 MkII due to its simple to read LCD screen and user-friendly interface. Software for fault diagnostics and a configurable calibration period keep maintenance tasks as easy as can be.

Detection that can be relied on is just one of the features of the Honeywell Series 3000 MkII which features an explosion proof build. The device is able to be either pole or wall mounted and has overall reduced installation and commissioning costs. It is a two wire loop powered oxygen and toxic gas detector. The display (which shows a visual gas reading) is powered by an industry standard 4-20mA gas transmitter.

Accessories include a Duct Mounting Kit, Remote Mounting Kit, Collecting Cone and Calibration Cup. Speak to us today if you would like any advice and guidance on whether this is the device you need for your environment or to receive a competitive price on the Series 3000 MkII fixed gas detector and any associated accessories you require. Our team has years of experience in the industry and we provide a full suite of after-sales services to ensure you are well supported and able to focus on the job.

One of the many benefits of the Series 3000 MkII is that users can configure the device without the need for a ‘hot work permit’ via the inbuilt LCD and magnetic switches.

Honeywell Series 3000 Mkll Transmitter Features

  • Electrochemical sensing technology provides reliable detection
  • Universal mounting provided reduced installation costs
  • Reduced commissioning costs via plug and play factory config sensors
  • Hot swappable components reduce maintenance costs and downtime
  • Continuous 20-90% operating humidity
  • 90-110kPa operating pressure
honeywell series 3000 mkII transmitter - closeup

Detectable Gases

Series 3000 MKII Detectable Gases
GasFormulaSelectable Full Scale RangeDefault RangeOperating Temperature (Min)Operating Temperature (Max)
OxygenO225.0% / Vol only25.0%Vol-30°C / -22°F55°C / 131°F
Hydrogen SulphideH2S10.0 to 50.0ppm15.0ppm-40°C / -40°F55°C / 131°F
Hydrogen SulphideH2S50 to 500ppm100ppm40°C / -40°F55°C / 131°F
Carbon MonoxideCO100 to 500ppm300ppm-40°C / -40°F55°C / 131°F
Sulphur DioxideSO25.0 to 20.0ppm15.0ppm-40°C / -40°F55°C / 131°F
Ammonia*NH350 to 200ppm200ppm20°C / -4°F40°C / 104°F1
Ammonia*NH3200 to 1,000ppm1,000ppm-20°C / -4°F40°C / 104°F
ChlorineCI25.0 to 20ppm5.0ppm-10°C / 14°F55°C / 131°F
Chlorine DioxideCIO21.00ppm only1.00ppm-20°C / -4°F55°C / 131°F
Nitric OxideNO100ppm only100ppm-20°C / -4°F55°C / 131°F
Nitrogen DioxideNO25.0 to 50.0ppm10ppm-20°C / -4°F55°C / 131°F
HydrogenH21,000ppm only1,000ppm-20°C / -4°F55°C / 131°F
HydrogenH29,999ppm only9,999ppm-20°C / -4°F55°C / 131°F
Hydrogen ChlorideHCI10.0 to 20.0ppm10ppm-20°C / -4°F40°C / 104°F
Hydrogen CyanideHCN30.0ppm only30.0ppm20°C / -4°F55°C / 131°F
Hydrogen FluorideHF12.0ppm only12.0ppm-20°C / -4°F55°C / 131°F
PhosphinePH31.2ppm only1.2ppm-20°C / -4°F40°C / 104°F
FluorineF24.00ppm only4.00ppm-20°C / -4°F55°C / 131°F
OzoneO30.400ppm only0.400ppm-20°C / -4°F55°C / 131°F
Ethylene OxideETO20.0 to 50.0ppm25.0ppm-20°C / -4°F55°C / 131°F

Technical Specifications

Series 3000 MKII Technical Specifications
SpecificationDescription
Connections and Power2-wire loop powered

17Vdc (±10%) to 32Vdc (max)

22mA max. over range

Recommended Cable2-wire with screen (90% coverage) or conduit
0.5mm2
(20AWG) to 2.0mm2
(14AWG)
Signal0-100% FSD 4-20mA

Fault = 3mA

Calibration due selectable off or 3mA

Max. over range 22mA
Inhibit (toxic sensors) = Selectable 3mA or 4mA

Inhibit (Oxygen sensors) = Selectable 3mA or 17.4mA

MaterialTransmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel, Sensor: 316 Stainless Steel with PTFE filter
Maximum Dimensions164mm x 201mm x 99mm (6.4” x 7.9” x 3.9”)
WeightAluminium alloy LM25: 1.7kg (3.75lbs.) Stainless Steel 316: 3.7kg (8.16lbs.)
IP RatingIP66 (EN 60529), NEMA 4X
Certified TemperatureATEX/IECEX: -20°C to +55°C (-4°F to +131°F) (MkIII -40°C to +55°C (-40°F to +131°F))
UL/c-UL: -40°C to +55°C (-40°F to +131°F)
Operating HumidityContinuous 20-90% RH (non-condensing) Intermittent 0-99% RH (non-condensing)
Operating Pressure90-110kPa
Storage Conditions15°C to 30°C (59°F to 86°F), 30-70% RH (non-condensing)
CertificationUL/c-UL: Class I, Div. 1 & 2, Groups B, C & D;
Class II, Div. 1 Groups E, F & G, Class II, Div. 2, Groups
F & G; Class I, Zone 1, Group IIB + H2 Hazardous
Locations

ATEX: II 2 (1) GD Ex d [ia IIC Ga] IIB + H2 T4 Gb
Ex t [ia IIIC Da] IIIB T135°C Db

IECEx: Ex d [ia IIC Ga] IIB + H2 T4 Gb Ex t [ia IIIC Da]
IIIB T135°C DbApprovalsCE compliant in accordance with: ATEX Directive 94/9/EC, EMC Directive 2004/108/EC, EN 50270

We are here to help

Please don’t hesitate to contact our highly trained and knowledgeable ADT staff to determine what type of system would best fit your needs.

Phone:
(02) 4577 9347

Email:
[email protected]

Address:
5 Aspinall Place,
Mulgrave 2756
NSW