Sensepoint XCD RFD

Home/Sensepoint XCD RFD
(02) 4577 9347
Sensepoint XCD RFD Fixed Gas Detector
BW Technologies by Honeywell

Your most flexible, practical choice for remote flammable gas monitoring in Class 1, Div 1 areas.

Sensepoint XCD RFD (Remote Flammable Detector) has been specifically designed for use with remotely mounted flammable gas sensors. This configuration is ideal for applications where the sensor is required to be mounted remotely from the transmitter in areas where temperatures are well above ambient (up to 150°C/302°F), or that are difficult to access. The transmitter can be mounted at a suitable location away from this area where it is easy to access, view its display and interact with via the user interface.

  • Accurate detection with fast response

  • Mount sensor up to 100 ft. from transmitter

  • Easy to read tri-color backlit display

  • Pole or wall mounting

  • Methane

  • Hydrogen

  • Butane

  • Propane

  • Pentane

  • Ethylene

Get a fast quote
Call Our Friendly Team!

Downloads

Sensepoint XCD RFD Brochure
Sensepoint XCD RFD User Manual
Sensepoint XCD RFD Quick Guide

Quick Specs

  • Input voltage range: 16 to 32 VDC (24 VDC nominal)
  • Communication: RS485, MODBUS RTU
  • Mounting: Pole or wall
Item Detail
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Max 5 Watts. at 24Vdc (see section 2 regarding maximum in rush current)
Current Output 4-20mA (Source or Sink)
≥0.0<1.0 mA: Fault
4.0 mA to 20.0 mA: Inhibit (during configuration/user settings)
22.0 mA: Maximum over range
Terminals 15 x screw terminals suitable for wire diameter 0.5mm2 to 2.5mm 2 (20AWG to 13AWG)
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energized (programmable)
Communication RS485, Modbus RTU
Material Epoxy painted aluminium alloy or 316 Stainless Steel
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Pole or wall mounting
Cable Entries 2 x ¾” NPT
Sensor Entries ¾” NPT
IP Rating IP66 in accordance with EN60529:1992, NEMA 4X (Tested by third party laboratory)
Operating Temperature -40ºF to +149ºF (-40ºC to +65ºC)
Operating Humidity Continuous 20-90%RH (non condensing), Intermittent 10-99%RH (non condensing)
Operating Pressure 90-110kPa
Storage Conditions -13°F to +149°F (-25°C to +65°C)
Certification cCSAus approved for Class I, Division 1, Groups B, C & D Hazardous Locations. Performance approved to the following standards; ANSI/ISA-12.13.01
Gas Displayed Name 705/705HT Sensor Calibration Gas
Methane** CH4 50% Methane/air
Hydrogen H2 50% Hydrogen/air
Butane C4H10 50% Butane/air
Propane C3H8 50% Propane/air
Pentane C5H12 50% Pentane/air
Ethylene C2H4 50% Ethylene/air